enum bl_input_reg {
BL_INPUT_MAGIC_HI = 0xe000,
BL_INPUT_MAGIC_LO,
BL_INPUT_LOADER_VERSION,
BL_INPUT_STATUS,
// The following registers are not available in application mode
BL_INPUT_VENDOR_ID,
BL_INPUT_DEVICE_ID,
BL_INPUT_SERIAL_NUMBER, // 12 characters as in USB
BL_INPUT_BLOCK_SIZE = BL_INPUT_SERIAL_NUMBER + 6,
BL_INPUT_FLASH_SIZE, // kB
BL_INPUT_MAX,
};
enum bl_holding_reg {
BL_HOLD_COMMAND = 0xe000,
BL_HOLD_BLOCK_NUMBER,
BL_HOLD_MAX,
BL_HOLD_BLOCK_DATA = BL_HOLD_COMMAND + 0x100, // next BL_BLOCK_SIZE/2 registers contain block data
};
#define BL_MAGIC_HI 0x426f // "Bo"
#define BL_MAGIC_LO 0x6f54 // "oT"
#define BL_LOADER_VERSION 0x0001
enum bl_status {
BL_STATUS_APP = 1, // In application code, needs exit command
BL_STATUS_READY, // Boot loader ready
BL_STATUS_FLASHING, // Flashing in progress
BL_STATUS_ERROR, // Error occurred
BL_STATUS_CORRUPTED, // Corrupted firmware found
BL_STATUS_BOOTING, // About to boot current firmware
};
enum bl_command {
BL_COMMAND_BOOT = 1, // Boot current firmware
BL_COMMAND_FLASH_START, // Enter flash mode
BL_COMMAND_FLASH_END, // Quit flash mode and verify checksum
BL_COMMAND_FLASH_BLOCK, // Flash one block
BL_COMMAND_EXIT_APP, // Exit from application code to boot loader
};
static inline bool bl_app_check_input_register(u16 addr)
{
switch (addr) {
case BL_INPUT_MAGIC_HI:
case BL_INPUT_MAGIC_LO:
case BL_INPUT_LOADER_VERSION:
case BL_INPUT_STATUS:
return true;
default:
return false;
}
}
static inline u16 bl_app_get_input_register(u16 addr)
{
switch (addr) {
case BL_INPUT_MAGIC_HI:
return BL_MAGIC_HI;
case BL_INPUT_MAGIC_LO:
return BL_MAGIC_LO;
case BL_INPUT_LOADER_VERSION:
return BL_LOADER_VERSION;
case BL_INPUT_STATUS:
return BL_STATUS_APP;
default:
return 0;
}
}
static inline bool bl_app_check_holding_register(u16 addr)
{
return (addr == BL_HOLD_COMMAND);
}
static inline bool bl_app_set_holding_register(u16 addr, u16 value)
{
return (addr == BL_HOLD_COMMAND && value == BL_COMMAND_EXIT_APP);
}